mirror of
https://github.com/nekorevend/esphome-emporia-vue-utility.git
synced 2026-01-08 20:40:39 -07:00
Merge remote-tracking branch 'upstream/main'
This commit is contained in:
@@ -50,10 +50,12 @@ class EmporiaVueUtility : public Component, public UARTDevice {
|
||||
Sensor *kWh_net = new Sensor();
|
||||
Sensor *kWh_consumed = new Sensor();
|
||||
Sensor *kWh_returned = new Sensor();
|
||||
Sensor *Wh_net = new Sensor();
|
||||
Sensor *Wh_consumed = new Sensor();
|
||||
Sensor *Wh_returned = new Sensor();
|
||||
Sensor *W = new Sensor();
|
||||
Sensor *Wh_net = new Sensor();
|
||||
Sensor *Wh_consumed = new Sensor();
|
||||
Sensor *Wh_returned = new Sensor();
|
||||
Sensor *W = new Sensor();
|
||||
Sensor *W_consumed = new Sensor();
|
||||
Sensor *W_returned = new Sensor();
|
||||
|
||||
const char *TAG = "Vue";
|
||||
const uint8_t meter_reading_interval;
|
||||
@@ -531,6 +533,13 @@ class EmporiaVueUtility : public Component, public UARTDevice {
|
||||
last_reading_has_error = 1;
|
||||
} else {
|
||||
W->publish_state(watts);
|
||||
if (watts > 0) {
|
||||
W_consumed->publish_state(watts);
|
||||
W_returned->publish_state(0);
|
||||
} else {
|
||||
W_consumed->publish_state(0);
|
||||
W_returned->publish_state(-watts);
|
||||
}
|
||||
}
|
||||
return(watts);
|
||||
}
|
||||
@@ -550,6 +559,13 @@ class EmporiaVueUtility : public Component, public UARTDevice {
|
||||
last_reading_has_error = 1;
|
||||
} else {
|
||||
W->publish_state(watts);
|
||||
if (watts > 0) {
|
||||
W_consumed->publish_state(watts);
|
||||
W_returned->publish_state(0);
|
||||
} else {
|
||||
W_consumed->publish_state(0);
|
||||
W_returned->publish_state(-watts);
|
||||
}
|
||||
}
|
||||
return(watts);
|
||||
}
|
||||
@@ -601,7 +617,7 @@ class EmporiaVueUtility : public Component, public UARTDevice {
|
||||
int handle_resp_firmware_ver() {
|
||||
struct Ver *ver;
|
||||
ver = &input_buffer.ver;
|
||||
|
||||
|
||||
mgm_firmware_ver = ver->value;
|
||||
|
||||
ESP_LOGI(TAG, "MGM Firmware Version: %d", mgm_firmware_ver);
|
||||
@@ -682,6 +698,19 @@ class EmporiaVueUtility : public Component, public UARTDevice {
|
||||
|
||||
msg_len = read_msg();
|
||||
now = ::time(&now);
|
||||
|
||||
/* sanity checks! */
|
||||
if (next_meter_request >
|
||||
now + (INITIAL_STARTUP_DELAY + METER_REJOIN_INTERVAL)) {
|
||||
ESP_LOGD(TAG,
|
||||
"Time jumped back (%lld > %lld + %lld); resetting",
|
||||
(long long) next_meter_request,
|
||||
(long long) now,
|
||||
(long long) (INITIAL_STARTUP_DELAY +
|
||||
METER_REJOIN_INTERVAL));
|
||||
next_meter_request = next_meter_join = 0;
|
||||
}
|
||||
|
||||
if (msg_len != 0) {
|
||||
|
||||
msg_type = input_buffer.data[2];
|
||||
@@ -761,9 +790,8 @@ class EmporiaVueUtility : public Component, public UARTDevice {
|
||||
}
|
||||
|
||||
if (now >= next_meter_request) {
|
||||
|
||||
// Handle initial startup delay
|
||||
if (next_meter_request == 0) {
|
||||
// Handle initial startup delay
|
||||
if (next_meter_request == 0) {
|
||||
next_meter_request = now + INITIAL_STARTUP_DELAY;
|
||||
next_meter_join = next_meter_request + METER_REJOIN_INTERVAL;
|
||||
return;
|
||||
@@ -778,13 +806,12 @@ class EmporiaVueUtility : public Component, public UARTDevice {
|
||||
next_meter_join = now + METER_REJOIN_INTERVAL;
|
||||
return;
|
||||
}
|
||||
|
||||
|
||||
if (startup_step == 0) send_version_req();
|
||||
else if (startup_step == 1) send_mac_req();
|
||||
else if (startup_step == 2) send_install_code_req();
|
||||
else if (startup_step == 3) send_meter_join();
|
||||
else send_meter_request();
|
||||
|
||||
}
|
||||
}
|
||||
};
|
||||
|
||||
@@ -25,7 +25,7 @@ api:
|
||||
|
||||
mqtt:
|
||||
broker: !secret mqtt_broker
|
||||
id: vue-utility
|
||||
id: vue_utility
|
||||
username: !secret mqtt_username
|
||||
password: !secret mqtt_password
|
||||
discovery: False # Only if you use the HA API usually
|
||||
@@ -42,7 +42,7 @@ sensor:
|
||||
lambda: |-
|
||||
auto vue = new EmporiaVueUtility(id(emporia_uart));
|
||||
App.register_component(vue);
|
||||
return {vue->kWh_consumed, vue->kWh_returned, vue->W, vue->kWh_net};
|
||||
return {vue->kWh_consumed, vue->kWh_returned, vue->W_consumed, vue->W_returned, vue->W, vue->kWh_net};
|
||||
sensors:
|
||||
- name: "kWh Consumed"
|
||||
id: kWh_consumed
|
||||
@@ -88,6 +88,44 @@ sensor:
|
||||
lambda: |-
|
||||
ESP_LOGI("Vue", "kWh = %0.3f", x);
|
||||
|
||||
- name: "Watts consumed"
|
||||
id: watts_consumed
|
||||
unit_of_measurement: "W"
|
||||
accuracy_decimals: 0
|
||||
state_class: measurement
|
||||
device_class: power
|
||||
# Report every 5 minutes or when +/- 20 watts
|
||||
filters:
|
||||
- or:
|
||||
- throttle: 5min
|
||||
- delta: 20 # <- watts
|
||||
- lambda: |-
|
||||
if (id(fast_reporting)) return(x);
|
||||
return {};
|
||||
on_raw_value:
|
||||
then:
|
||||
lambda: |-
|
||||
ESP_LOGI("Vue", "Watts consumed = %0.3f", x);
|
||||
|
||||
- name: "Watts returned"
|
||||
id: watts_returned
|
||||
unit_of_measurement: "W"
|
||||
accuracy_decimals: 0
|
||||
state_class: measurement
|
||||
device_class: power
|
||||
# Report every 5 minutes or when +/- 20 watts
|
||||
filters:
|
||||
- or:
|
||||
- throttle: 5min
|
||||
- delta: 20 # <- watts
|
||||
- lambda: |-
|
||||
if (id(fast_reporting)) return(x);
|
||||
return {};
|
||||
on_raw_value:
|
||||
then:
|
||||
lambda: |-
|
||||
ESP_LOGI("Vue", "Watts returned = %0.3f", x);
|
||||
|
||||
- name: "Watts"
|
||||
id: watts
|
||||
unit_of_measurement: "W"
|
||||
|
||||
@@ -25,7 +25,7 @@ api:
|
||||
|
||||
mqtt:
|
||||
broker: !secret mqtt_broker
|
||||
id: vue-utility
|
||||
id: vue_utility
|
||||
username: !secret mqtt_username
|
||||
password: !secret mqtt_password
|
||||
discovery: False # Only if you use the HA API usually
|
||||
|
||||
Reference in New Issue