mirror of
https://github.com/nekorevend/esphome-emporia-vue-utility.git
synced 2026-01-08 20:40:39 -07:00
Apply meter divisor calculation to all spots in V2 and V7.
This commit is contained in:
@@ -275,6 +275,11 @@ class EmporiaVueUtility : public PollingComponent, public uart::UARTDevice {
|
||||
return x;
|
||||
}
|
||||
|
||||
float apply_watt_adjustment(int64_t input, uint8_t meter_div,
|
||||
uint16_t cost_unit) {
|
||||
return ((float)input * (float)meter_div) / ((float)cost_unit / 1000.0);
|
||||
}
|
||||
|
||||
void handle_resp_meter_reading() {
|
||||
int32_t input_value;
|
||||
float watt_hours;
|
||||
@@ -295,26 +300,14 @@ class EmporiaVueUtility : public PollingComponent, public uart::UARTDevice {
|
||||
}
|
||||
|
||||
// Setup Meter Divisor
|
||||
if ((mr2->meter_div > 10) || (mr2->meter_div < 1)) {
|
||||
ESP_LOGW(TAG, "Unreasonable MeterDiv value %d, ignoring",
|
||||
mr2->meter_div);
|
||||
last_reading_has_error = 1;
|
||||
ask_for_bug_report();
|
||||
} else if ((meter_div != 0) && (mr2->meter_div != meter_div)) {
|
||||
ESP_LOGW(TAG, "MeterDiv value changed from %d to %d", meter_div,
|
||||
mr2->meter_div);
|
||||
last_reading_has_error = 1;
|
||||
meter_div = mr2->meter_div;
|
||||
} else {
|
||||
meter_div = mr2->meter_div;
|
||||
}
|
||||
meter_div = parse_meter_div(mr2->meter_div);
|
||||
|
||||
// Setup Cost Unit
|
||||
cost_unit =
|
||||
((mr2->cost_unit & 0x00FF) << 8) + ((mr2->cost_unit & 0xFF00) >> 8);
|
||||
|
||||
watt_hours = parse_meter_watt_hours_v2(mr2);
|
||||
watts = parse_meter_watts_v2(mr2);
|
||||
watts = parse_meter_watts_v2(mr2->watts);
|
||||
|
||||
// Extra debugging of non-zero bytes, only on first packet or if
|
||||
// debug_ is true
|
||||
@@ -352,15 +345,20 @@ class EmporiaVueUtility : public PollingComponent, public uart::UARTDevice {
|
||||
return;
|
||||
}
|
||||
|
||||
// Setup Meter Divisor
|
||||
meter_div = parse_meter_div(mr7->meter_div);
|
||||
|
||||
// Setup Cost Unit
|
||||
cost_unit = mr7->cost_unit;
|
||||
watts = parse_meter_watts_v7(mr7);
|
||||
|
||||
watts = parse_meter_watts_v7(mr7->watts);
|
||||
watt_hours = parse_meter_watt_hours_v7(mr7);
|
||||
|
||||
// Extra debugging of non-zero bytes, only on first packet or if
|
||||
// debug_ is true
|
||||
if ((debug_) || (last_meter_reading == 0)) {
|
||||
ESP_LOGD(TAG, "Meter Cost Unit: %d", cost_unit);
|
||||
ESP_LOGD(TAG, "Meter Divisor: %d", mr7->meter_div);
|
||||
ESP_LOGD(TAG, "Meter Divisor: %d", meter_div);
|
||||
ESP_LOGD(TAG, "Meter Energy Import Flags: %08x", mr7->import_wh);
|
||||
ESP_LOGD(TAG, "Meter Energy Export Flags: %08x", mr7->export_wh);
|
||||
ESP_LOGD(TAG, "Meter Power Flags: %08x", mr7->watts);
|
||||
@@ -406,6 +404,23 @@ class EmporiaVueUtility : public PollingComponent, public uart::UARTDevice {
|
||||
ESP_LOGE(TAG, "EOF");
|
||||
}
|
||||
|
||||
uint8_t parse_meter_div(uint8_t new_meter_div) {
|
||||
uint8_t div;
|
||||
if ((new_meter_div > 10) || (new_meter_div < 1)) {
|
||||
ESP_LOGW(TAG, "Unreasonable MeterDiv value %d, ignoring", new_meter_div);
|
||||
last_reading_has_error = 1;
|
||||
ask_for_bug_report();
|
||||
} else if ((meter_div != 0) && (new_meter_div != meter_div)) {
|
||||
ESP_LOGW(TAG, "MeterDiv value changed from %d to %d", meter_div,
|
||||
new_meter_div);
|
||||
last_reading_has_error = 1;
|
||||
div = new_meter_div;
|
||||
} else {
|
||||
div = new_meter_div;
|
||||
}
|
||||
return div;
|
||||
}
|
||||
|
||||
float parse_meter_watt_hours_v2(struct MeterReadingV2 *mr) {
|
||||
// Keep the last N watt-hour samples so invalid new samples can be discarded
|
||||
static float history[MAX_WH_CHANGE_ARY];
|
||||
@@ -433,7 +448,7 @@ class EmporiaVueUtility : public PollingComponent, public uart::UARTDevice {
|
||||
}
|
||||
|
||||
// Handle if a meter divisor is in effect
|
||||
watt_hours = (float)watt_hours_raw * (float)meter_div;
|
||||
watt_hours = apply_watt_adjustment(watt_hours_raw, meter_div, cost_unit);
|
||||
|
||||
if (!not_first_run) {
|
||||
// Initialize watt-hour filter on first run
|
||||
@@ -505,8 +520,8 @@ class EmporiaVueUtility : public PollingComponent, public uart::UARTDevice {
|
||||
static uint32_t prev_returned;
|
||||
int32_t net = 0;
|
||||
|
||||
consumed = mr->import_wh;
|
||||
returned = mr->export_wh;
|
||||
consumed = apply_watt_adjustment(mr->import_wh, meter_div, cost_unit);
|
||||
returned = apply_watt_adjustment(mr->export_wh, meter_div, cost_unit);
|
||||
int32_t consumed_diff = int32_t(consumed) - int32_t(prev_consumed);
|
||||
int32_t returned_diff = int32_t(returned) - int32_t(prev_returned);
|
||||
|
||||
@@ -561,36 +576,36 @@ class EmporiaVueUtility : public PollingComponent, public uart::UARTDevice {
|
||||
*
|
||||
* For MGM version 2 (to 6?)
|
||||
*/
|
||||
float parse_meter_watts_v2(struct MeterReadingV2 *mr) {
|
||||
int32_t watts_raw;
|
||||
float parse_meter_watts_v2(int32_t watts_raw) {
|
||||
int32_t watts_24bit;
|
||||
float watts;
|
||||
|
||||
// Read the instant watts value
|
||||
// (it's actually a 24-bit int)
|
||||
watts_raw = (endian_swap(mr->watts) & 0xFFFFFF);
|
||||
watts_24bit = (endian_swap(watts_raw) & 0xFFFFFF);
|
||||
|
||||
// Bit 1 of the left most byte indicates a negative value
|
||||
if (watts_raw & 0x800000) {
|
||||
if (watts_raw == 0x800000) {
|
||||
if (watts_24bit & 0x800000) {
|
||||
if (watts_24bit == 0x800000) {
|
||||
// Exactly "negative zero", which means "missing data"
|
||||
ESP_LOGI(TAG, "Instant Watts value missing");
|
||||
return (0);
|
||||
} else if (watts_raw & 0xC00000) {
|
||||
} else if (watts_24bit & 0xC00000) {
|
||||
// This is either more than 12MW being returned,
|
||||
// or it's a negative number in 1's complement.
|
||||
// Since the returned value is a 24-bit value
|
||||
// and "watts" is a 32-bit signed int, we can
|
||||
// get away with this.
|
||||
watts_raw -= 0xFFFFFF;
|
||||
watts_24bit -= 0xFFFFFF;
|
||||
} else {
|
||||
// If we get here, then hopefully it's a negative
|
||||
// number in signed magnitude format
|
||||
watts_raw = (watts_raw ^ 0x800000) * -1;
|
||||
watts_24bit = (watts_24bit ^ 0x800000) * -1;
|
||||
}
|
||||
}
|
||||
|
||||
// Handle if a meter divisor is in effect
|
||||
watts = (float)watts_raw * (float)meter_div;
|
||||
// Handle the adjustment.
|
||||
watts = apply_watt_adjustment(watts_24bit, meter_div, cost_unit);
|
||||
|
||||
if ((watts >= WATTS_MAX) || (watts < WATTS_MIN)) {
|
||||
ESP_LOGE(TAG, "Unreasonable watts value %f", watts);
|
||||
@@ -623,13 +638,11 @@ class EmporiaVueUtility : public PollingComponent, public uart::UARTDevice {
|
||||
*
|
||||
* For MGM version 7 and 8
|
||||
*/
|
||||
float parse_meter_watts_v7(struct MeterReadingV7 *mr) {
|
||||
float parse_meter_watts_v7(int32_t watts_raw) {
|
||||
// Read the instant watts value
|
||||
// (it's actually a 24-bit int)
|
||||
int32_t watts_raw = mr->watts;
|
||||
watts_raw >>= 8;
|
||||
float watts = ((float)watts_raw * (float)mr->meter_div) /
|
||||
((float)mr->cost_unit / 1000.0);
|
||||
float watts = apply_watt_adjustment(watts_raw, meter_div, cost_unit);
|
||||
|
||||
if ((watts >= WATTS_MAX) || (watts < WATTS_MIN)) {
|
||||
ESP_LOGE(TAG, "Unreasonable watts value %d", watts);
|
||||
|
||||
Reference in New Issue